TITLE

Study on the Static Load Capacity and Synthetic Vector Direct Torque Control of Brushless Doubly Fed Machines

AUTHOR(S)
Chaoying Xia; Xiaoxin Hou
PUB. DATE
November 2016
SOURCE
Energies (19961073);Nov2016, Vol. 9 Issue 11, p966
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Compared to the doubly fed machine, the brushless doubly fed machine (BDFM) has high reliability and low maintenance requirements. First, by taking the negative conjugation of the control motor variables in rotor reference frame, a state-space model of BDFM is derived. It is then transformed into synchronous reference frame, called synchronous reference frame state-space model (SSSM). In this way, all the variables of the SSSM are DC under the static state. Second, on the basis of the analysis of static equations, the possible output torque limits are obtained. Third, the causes of losing control are analyzed by the flux and the torque derivatives. A new control strategy called synthetic vector direct torque control (SVDTC) is proposed to solve the losing control problems of the conventional direct torque control (DTC). Finally, the correctness of the results of this paper is verified by calculation examples and simulation results, the losing control problems can be solved, and the theoretical output capacity limits can be reached using SVDTC.
ACCESSION #
119725184

 

Related Articles

  • Main Aspects Regarding the Screw-on Torque Diminishing when Using the Fine Pitch Screw. CreiĆŁaru, Adrian // Petroleum - Gas University of Ploiesti Bulletin, Technical Serie;2012, Vol. 64 Issue 2, p71 

    Romanian special standards - according to international (ISO) ones - show metric threads of common use for this kind of screw elements (bolts, nuts); there are a lot of standardized and un-standardized variants and also for any mechanical threaded pieces. In usual practice, the threads are...

  • UP TO 15 PERCENT FUEL SAVINGS.  // Rock Products;May2013, Vol. 116 Issue 5, p22 

    The article features Volvo's Optishift system which consists of a new torque converter with Lock Up and free wheel stator.

  • Control Strategy in the Flux Weakening Region of Interior Permanent Magnet Synchronous Machine used in HEV. Xiaohong Liu; Youtong Zhang // Applied Mechanics & Materials;2014, Issue 543-547, p1322 

    An new control strategy for interior permanent magnet synchronous machine (IPMSM) which is the most popular motor used in HEV is proposed and investigated, which features is increasing the reference flux weakening voltage to improve efficiency in flux weakening region. Modeling results show that...

  • Rusted but not Busted PART 3. AGUILAR, KEVIN // Street Trucks;Jan2015, Vol. 17 Issue 1, p82 

    The article offers step by step instruction for making and installing custom calibrated torque converter.

  • Behind the MVSD vs. VFD debate. Almasi, Amin // Manufacturers' Monthly;Feb2013, p28 

    The article focuses on Mechanical variable-speed drives (MVSD) which are used in rotating machineries. The drive consists of planetary gear system and is employed with hydraulic torque converters. An effective cost analysis is conducted to determine the use of such machines. Although the drive...

  • ABB - Leading the Way in Electric Motors and Drives.  // Automotive Industries;Jul2007, Vol. 187 Issue 7, p1 

    An interview with ABB's Business Unit Low Voltage Drives head and group vice president Pekka Tiitinen is presented. When asked about the advantages of DTC-based products, he referred to its fast inner torque control loop and high starting torque at zero speed. He highlights the new test bench...

  • Behind the MVSD vs. VFD debate. Almasi, Amin // Process & Control Engineering (PACE);Dec2012, Vol. 65 Issue 11, p22 

    The article presents a comparison regarding the features of the mechanical variable-speed drives (MVSDs) and variable-frequency drives (VFDs) in the process control equipment industry in Australia. It highlights the advantages and disadvantages of using MVSDs over VFDs. It informs that hydraulic...

  • Evaluation of the Accuracy and Related Factors of the Mechanical Torque-Limiting Device for Dental Implants. Kazemi, Mahmood; Rohanian, Ahmad; Monzavi, Abbas; Sadegh Nazari, Mohammad // Journal of Dentistry of Tehran University of Medical Sciences;Mar2013, Vol. 10 Issue 2, p112 

    Objective: Accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. Mechanical torque-limiting devices (MTLDs) are available for this reason. In this study, the accuracy of one type of friction-style...

  • Reduction of EMI with Chaotic Space Vector Modulation in Direct Torque Control. Asker, Mehmet Emin; Ozer, Ahmet Bedri; Kurum, Hasan // Electronics & Electrical Engineering;2016, Vol. 22 Issue 1, p40 

    In this paper a study is presented about the reduction of electromagnetic interference (EMI) in Direct Torque Control (DTC) method by the means of chaotic space vector modulation. Space Vector Modulated Direct Torque Control (SV-DTC) is a method developed to reduce current and moment...