TITLE

SOME DEVELOPMENTS IN NEUTRON AND CHARGED PARTICLE DOSIMETRY

AUTHOR(S)
Bos, Adrie J.; d'Errico, Francesco
PUB. DATE
September 2006
SOURCE
Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p331
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
There is an increasing need for dosimetry of neutrons and charged particles. Increasing exposure levels are reported in the nuclear industry, deriving from more frequent in-service entries at commercial nuclear power plants, and from increased plant decommissioning and refurbishment activities. Another need stems from the compliance with requirements of the regulations and standards. The European Council directive 96/29 requires dosimetric precautions if the effective dose exceeds 1 mSv a-1. On average, aircrew members exceed this value. Further, there is a trend of increasing use of charged particles in radiotherapy. The present situation is that we have reasonably good photon dosemeters, but neutron and charged particle dosemeters are still in need of improvements. This work highlights some of the developments in this field. It is mainly concentrated on some developments in passive dosimetry, in particular thermally and optically stimulated luminescent detectors, indicating the direction of ongoing research. It shows that passive dosemeters are still a very active field. Active dosemeters will not be discussed with the exception of new developments in microdosimetric measurements [new types of tissue equivalent proportional counters (TEPCs)]. The TEPC is unique in its ability to provide a simultaneous determination of neutron I charged particle I gamma ray doses, or dose equivalents using a single detector.
ACCESSION #
23154607

 

Related Articles

  • ELECTRONIC NEUTRON PERSONAL DOSEMETERS: THEIR PERFORMANCE IN MIXED RADIATION FIELDS IN NUCLEAR POWER PLANTS. M. Luszik-Bhadrai; Bartlett, D.; Boschung, M.; Coeck, M.; Curzio, G.; Derdau, D.; d'Errico, F.; Fiechtner, A.; Itié, C.; J.-E. Kyllönen; Lacoste, V.; Lahaye, L.; Lindborg, L.; Molinos, C.; Reginatto, M.; Schuhmacher, H.; Tanner, R.; Vanhavere, F. // Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p378 

    This work describes spectral distributions of neutrons obtained as function of energy and direction at four workplace fields at the Krümmel reactor in Germany. Values of personal dose equivalent Hp(10) and effective dose E are determined for different directions of a person's orientation in...

  • PHOTON AND FAST NEUTRON DOSIMETRY USING ALUMINIUM OXIDE THERMOLUMINESCENCE DOSEMETERS. Santos, J. P.; Fernandes, A. C.; Gonçalves, I. C.; Marques, J. G.; Carvaiho, A. F.; Santos, L.; Cardoso, J.; Osvay, M. // Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p358 

    Al2O3:Mg,Y thermoluminescence (TL) dosemeters were used to measure photon and fast neutron doses in a fast neutron beam recently implemented at the Portuguese Research Reactor, Nuclear and Technological Institute, Portugal. The activation of Al2O3:Mg,Y by fast neutrons provides information about...

  • Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry. Fiechtner, A.; Boschung, M.; Wernli, C. // Radiation Protection Dosimetry;Aug2007, Vol. 126 Issue 1-4, p314 

    In the framework of the EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields) project, funded by the EC, measurements with PADC personal neutron dosemeters were carried out at several workplace fields of the nuclear industry and at simulated workplace fields....

  • INTER-COMPARISON AMONG DIFFERENT TLD-BASED TECHNIQUES IN A STANDARD MULTISPHERE ASSEMBLY FOR THE CHARACTERISATION OF NEUTRON FIELDS. Bedogni, R.; Angelone, M.; Esposito, A.; Chiti, M. // Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p369 

    In the framework of collaboration among the ENEA Radiation Protection Institute (Bologna), the ENEA Fusion Department (Frascati) and the INFN-LNF-Radiation Protection Group (Frascati), an experimental campaign was organised on the usage of thermoluminescence dosemeters (TLDs) for the dosimetric...

  • DOSIMETRY AT THE PORTUGUESE RESEARCH REACTOR USING THERMOLUMINESCENCE MEASUREMENTS AND MONTE CARLO CALCULATIONS. Fernandes, A. C.; Gonçalves, I. C.; Santos, J.; Cardoso, J.; Santos, L.; Ferro Carvaiho, A.; Marques, J. G.; Kling, A.; Ramaiho, A. J. G.; Osvay, M. // Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p349 

    This work presents an extensive study on Monte Carlo radiation transport simulation and thermoluminescent (TL) dosimetry for characterising mixed radiation fields (neutrons and photons) occurring in nuclear reactors. The feasibility of these methods is investigated for radiation fields at...

  • Study of the glow curves of TLD exposed to thermal neutrons. Triolo, A.; Brai, M.; Marrale, M.; Gennaro, G.; Bartolotta, A. // Radiation Protection Dosimetry;Aug2007, Vol. 126 Issue 1-4, p333 

    The glow curves of thermoluminescent dosimeters (TLD600, TLD700 and MCP), exposed to a mixed field of thermal neutrons and γ photons are analysed. The fluence values of thermal neutrons used, comparable with those used in radiotherapy, allow one to define the reliability of the TLDs, in...

  • NEUTRON DOSIMETRY WITH 6LiF-RICH TL SHEET . Konnai, Akiko; Odano, Naoteru; Nariyama, Nobuteru; Ohnishi, Seiki; Nakajima, Nobuya; Yamamoto, Kazuyoshi; Kishi, Toshiaki; Ozasa, Naoto; Ishikawa, Yuhzoh // Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p133 

    A 6LiF-rich thermoluminescent sheet-type dosemeter (6LiF-rich NTL sheet) was developed for neutron 2D dosimetry. The dosemeter utilises the 6Li(n, a)³H reaction to detect thermal neutrons. Responses of the 6LiF-rich NTL sheet to neutrons were measured at the neutron beam irradiation facility...

  • PERFORMANCE OF THE ELECTRONIC PERSONAL DOSEMETER FOR NEUTRON `SAPHYDOSE-N' AT DIFFERENT WORKPLACES OF NUCLEAR FACILITIES. Lahaye, T.; Chaul, Q.; Ménard, S.; Lacoste, V.; Muller, H.; Luszik-Bhadra, M.; Reginatto, M.; Bruguier, P. // Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p383 

    This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and...

  • A Brazilian government external individual monitoring service: experience since 1972. Mauricio, Claudia L. P.; Martins, Marcelo M.; Ramos, Elisabete Vargas; Souza-Santos, Denison // Radiation Protection Dosimetry;Mar2011, Vol. 144 Issue 1-4, p130 

    Instituto de Radioproteção e Dosimetria, a Brazilian government research institute, provides individual monitoring services since 1972. Its dosemeters are: film-based thorax for whole body photons, thermoluminescence dosimetry (TLD) albedo for whole body neutrons and TLD ring for extremity...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics