TITLE

Power Cables Models with Frequency Dependent Parameters

AUTHOR(S)
Weens, Y.; Idir, N.; Franchaud, J. J.
PUB. DATE
November 2007
SOURCE
International Review of Electrical Engineering;Nov/Dec2007, Vol. 2 Issue 6, p763
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The fast commutation of the modern power semi-conductor devices is the main source of the conducted and radiated emissions generated by the power converters. These devices produce high voltage variations (dv/dt) which excite stray elements of the power circuit and induce high frequency parasitical currents that use the energy cables to be propagated in the whole of the system. In order to study the influence of the power cable characteristics on the level of the conducted emissions, it is necessary to elaborate a precise model of the energy cables, taking into account various phenomena that appear when the frequency increases. This paper proposes a high frequency modelling method of energy cable that takes into account the skin and proximity effects and dielectric losses. The proposed method is applied to the 3-wire unshielded cable and extended to the 4-wire shielded cable. The proposed models are validated in the frequency and time domains.
ACCESSION #
31240329

 

Related Articles

  • What drives choice in drives?  // Design Engineering;Jun2001, p22 

    Focuses on variable speed drives (VSD). Criteria in VSD selection; Comparison of AC, DC or servo drives; Control bandwidth; Areas of application; Lowest cost drive options.

  • Making drives meet the code. Petro, David // Machine Design;10/12/95, Vol. 67 Issue 18, p107 

    Offers tips on installing of variable-frequency drives (VFDs). Safety tips; Protecting VFDs; Feeder and ground-fault protection; Circuit breakers and switches; Branch short-circuit and ground-fault protection; Motor controllers; Motor overload protection. INSET: Underwriters Laboratories:...

  • quiz corner: Expressing Pump Discharge Pressure. Spitzer, David W. // Flow Control;Aug2009, Vol. 15 Issue 8, p48 

    A quiz related to variable speed drives, is presented.

  • Motor-drive compatibility. Langhorst, Phil; Hancock, Clyde // Engineered Systems;Nov96, Vol. 13 Issue 11, p57 

    Explains the reasons for the premature failure of windings and bearings when small- and medium-size motors and variable-frequency drives (vfds) are used together improperly. Description of how vfds create high-voltage pulses at the motor; Evidence of maximum voltage; Effect on electrical...

  • Performance analysis of self-controlled synchronous motors considering the effects of magnetic saturation. Sato, Tatsunori; Nishikata, Shoji; Ishizaki, Akira // Electrical Engineering in Japan;1/30/1997, Vol. 118 Issue 2, p56 

    A self-controlled synchronous motor, which has similar characteristics to a conventional dc motor, is being used in various industrial fields as an adjustable speed motor. The inductances in the motor are changed with change in the air-gap flux due to magnetic saturation (as in a field-weakening...

  • Slow work. Houlton, Sarah // Engineer (00137758);6/5/2006, Vol. 293 Issue 7701, p8 

    The article reports that Nottingham University engineers aim to design a drive that overcomes sensorless designs' inability to operate at zero or low speeds. The engineers coordinate with industrial partners TRW Automotive, Control Techniques, Smiths Aerospace Electronics and Power Electronic...

  • Drive for control.  // Engineer (00137758);4/11/2011, Vol. 296 Issue 7814, p42 

    The article discusses the role played by variable-speed drives (VSD) in making industrial plants and processes more efficient. It allows motors to be run more efficiently. The regenerative braking in VSD can save energy and makes it possible to achieve less expensive drive systems and more...

  • Variable-frequency Drives - Part 2. Pelikan, Bob // National Driller;Oct2009, Vol. 30 Issue 10, p30 

    The article presents the second part of the three-part series on variable-frequency drives (VFDs). It explores the basic concepts of use of VFDs. It cites the challenge faced by pumping system designers in meeting variable loads with a fixed-capacity pump. It also indicates the disadvantages of...

  • Vectorial Formalism of Polyphase Synchronous Machine With Permanents Magnets. Sellam, Abdelkrim; Dehiba, Boubakeur; Benabdallah, Mohamed B.; Abid, Mohamed; Bouiadjra, Nacéra Bachir; Bensaid, Boubakeur; Djouhri, Mustapha // Aceh International Journal of Science & Technology;Apr2013, Vol. 2 Issue 1, p1 

    This paper presents a mathematical model that transforms the real machine to fictitious machines and our goal is to simulate these and see the behavior of these machines in load. The polyphase machines are developed mainly in the field of variable speed drives of high power because increasing...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.