TITLE

Comparison of cone and mlc linac based arc stereotactic radiosurgery for small target with different apertures

AUTHOR(S)
K. Li
PUB. DATE
March 2013
SOURCE
Journal of Radiosurgery & SBRT;2013 Supplement 2.1, Vol. 2, p111
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Objectives: Stereotactic Radiosurgery (SRS) can utilize different techniques. For small target SRS, the selections of the apertures of cone or MLC field influence the treatment significantly. In this study, while the aperture of the MLC and cone field vary, the dosimetric characteristics of the two techniques are compared for SRS of small targets which are in the favor of magnifying the dosimetric effect. Method: An anthropomorphic phantom was used to simulate the patient with a 4 millimeter diameter cranial target. Single 360 ARC plans were generated with Eclipse external beam and cone based treatment planning system from Varian Medical System. For MLC based plan, the apertures fit to structure with circle margins varying with 2mm, 3mm, 4mm, 5mm and 6mm. These setups were in correspondence with the cones being selected to be 5mm, 10mm, 12mm, 14mm and 16mm in diameter. For the MLC based plan, the leaf-edge-contour meet points were selected to be in the middle. Jaw positions were used both recommended and optimized options. Mean dose was treated as the prescription dose. Comparison of the two planning techniques was carried out using 12Gy Volume (V12Gy) from dose-volume histogram (DVH), maximum dose to the prescription dose ratio (MDPD), ratio PITV (PIV/TV), radiation conformity index (TVPIV/TV), and an integrated conformity index (TVPIV2/(TVxPIV)), where PIV is the prescription isodose surface volume, TV is target volume, and TVPIV is the intersection of TV and the PIV. Results: For the apertures used for this study, while MLC and cone based plans were compared, the V12Gy ranges were from 1.0cc to 5.3cc with average at 3.3cc, and 0.1cc to 3.2cc with average value at 1.5cc. The variations of MDPD were 9% with average value at 1.04, and 12% with average at 1.03. The varying ranges of PITV were 35% with average value at 0.80, and 17% with average value at 0.54. Integrated conformity index (ICI) variations were up to 45% with average value at 0.34, and at the level of the 7% with average value at 0.42. Conclusions: For small target SRS, there are larger variations in V12Gy, PITV, and ICI in MLC based plan than those of cone based plan, while the difference is not significant for MDPD in both settings at the selected aperture sizes. The multiple ARC treatment plan and the clinical reality of algorithm for small aperture also need further investigation. Disclosure: No significant relationships.
ACCESSION #
92611256

 

Related Articles

  • Dosimetric analysis of modulated and hybrid arcs in stereotactic radiosurgery. Zhang, Geoffrey G.; Lichung Ku; Hsiang-Hsuan; Yu, Michael; Sarangkasiri, Siriporn; Zhang, Ray R.; Weiqi Li; Feygelman, Vladimir // Journal of Radiosurgery & SBRT;2011, Vol. 1 Issue 3, p177 

    Purpose: Forward-planned conformal arcs (termed dynamic arcs in the BrainLab iPlan system) have been routinely used in cranial stereotactic radiosurgery (SRS) for many years. This study compares dosimetric parameters of the newer, inversely-planned volumetric modulated arc therapy (VMAT) and...

  • Volumetric arc therapy for stereotactic body radiotherapy in early lung cancer. Hegi-Johnson, F.; Unicomb, K.; West, K.; Small, K.; White, S.; Barber, J.; Van Tilburg, K.; Yeghiaian-Alvandi, R. // Journal of Radiosurgery & SBRT;2013 Supplement 2.1, Vol. 2, p120 

    Introduction: Stereotactic body radiotherapy(SBRT) for early lung cancer results in excellent local control and potentially improved survival, but demands high levels of dose conformality. To achieve this with 3D-conformal radiotherapy(3D-CRT) and intensity modulated radiotherapy (IMRT) large...

  • Management of cerebral metastases: establishing the role of stereotactic radiosurgery in Canada. Bourque, J.; Roberge, D.; Monsalves, E.; Bauman, G.; Rodrigues, G.; Zadeh, G. // Journal of Radiosurgery & SBRT;2013 Supplement 2.1, Vol. 2, p36 

    Objectives: Stereotactic Radiosurgery (SRS) is increasingly being used in the treatment of brain metastases. Despite the availability of prospective trial data, uncertainties and variations persist in the application of SRS in specific clinical scenarios. Our objective was to determine the...

  • Dosimetric comparison between gamma knife plans and intensity-modulated radiotherapy plans for benign intracranial tumors. Nakazawa, H.; Mori, Y.; Tsugawa, T.; Hagiwara, M.; Komori, M.; Uchiyama, Y.; Kobayashi, T.; Hashizume, C. // Journal of Radiosurgery & SBRT;2013 Supplement 2.1, Vol. 2, p71 

    Purpose: Excellent clinical treatment results for various brain lesions by stereotactic irradiation, including both Gamma Knife (GK) stereotactic radiosurgery (SRS) and linear accelerator-based (LINAC) fractionated stereotactic radiotherapy (SRT) such as Novalis, have been reported. Novalis is...

  • Volumetric modulated arc radiotherapy sparing the thyroid gland for early-stage glottic cancer: A dosimetrical analysis. EUN SEOK KIM; SEUNG-GU YEO // Oncology Letters;2014, Vol. 7 Issue 6, p1987 

    Previous studies on advanced radiotherapy (RT) techniques for early stage glottic cancer have focused on sparing the carotid artery. However, the aim of the present study was to evaluate the dosimetric advantages of volumetric modulated arc therapy (VMAT) in terms of sparing the thyroid gland in...

  • The dosimetric impact of different photon beam energy on RapidArc radiotherapy planning for cervix carcinoma. Kumar, Lalit; Yadav, Girigesh; Raman, Kothanda; Bhushan, Manindra; Pal, Manoj // Journal of Medical Physics;Oct-Dec2015, Vol. 40 Issue 4, p207 

    The main purpose of this study is to know the effect of three different photon energies viz., 6, 10, and 15 mega voltage (MV) on RapidArc (RA) planning for deep-seated cervix tumor and to develop clinically acceptable RA plans with suitable photon energy. RA plans were generated for 6, 10, and...

  • Non-isocenteric approach in non-coplanar volumetric modulated arc therapy (VMAT) planning for lung SBRT treatments. S. Kim; T. Tseng; Dimitroyannis, D. // Journal of Radiosurgery & SBRT;2013 Supplement 2.1, Vol. 2, p84 

    Purpose: Volumetric Modulated Arc Therapy (VMAT) has emerged as an efficient alternative to traditional multi-beam, three-dimensional (3D), conformal techniques for lung cancer stereotactic body radiotherapy (SBRT) because of its superior dosimetric properties and its native ease in planning and...

  • Is it important to use monte carlo calculations for radiosurgery of the clivus? Ho, A. K.; Soltys, S. G.; Chang, S. D. // Journal of Radiosurgery & SBRT;2013 Supplement 2.1, Vol. 2, p71 

    Objectives: We sought to determine if dosimetric differences exist between Ray-Trace (RT) and Monte- Carlo (MC) calculation algorithms for radiosurgery for tumors of the clivus, given their proximity to air-tissue inhomogeneity. Methods: We retrospectively identified 6 patients with a tumor of...

  • Impact of Decaying Dose-rate in Gamma Knife Radiosurgery. Hopewell, John W.; Millar, William T.; Paddick, Ian; Lindquist, Christer // Journal of Radiosurgery & SBRT;2013, Vol. 2 Issue 3, p251 

    A letter to the editor is presented in response to the article "Impact of Decaying Dose Rate in Gamma Knife Radiosurgery: In Vitro Study on 9L Rat Gliosarcoma Cells" by A. Niranjan and colleagues in the 2012 issue.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library